German Italy France Spain China Japan Russia Korea
AC Axial IP Rated Fans
A9238DV Series
Size 92x92x38mm
(3.62"x3.62"x1.5")
 
General Specifications
Item Specification Condition
Model No. A9238DVHBL-C-IP55  
Outline Dimension 92X92X38 mm
Rated Voltage 110/220V AC
Rated Current IN FREE AIR RATED VOLTAGE 0.15A +/- 10% AT 220V/50Hz
IN FREE AIR RATED VOLTAGE 0.12A +/- 10% AT 110V/60Hz
Power Consumption IN FREE AIR RATED VOLTAGE 13 WATT +/- 10% AT 50Hz
IN FREE AIR RATED VOLTAGE 10 WATT +/- 10% AT 60Hz
Speed 2400 RPM +/- 10% AT 50Hz
2800 RPM +/- 10% AT 60Hz
At Rated Voltage, 25°C, 65% RH
Free Air
Max. Airflow 1.10 M3/min RATED VOLTAGE AT 50 Hz
1.30 M3/min RATED VOLTAGE AT 60 Hz
Max. Static Pressure 0.17 INCH-H2O AT 50HZ
0.20 INCH-H2O AT 60HZ
Noise Level 37 dBA At Rated Voltage
Measured in a non-echo Chamber
CNS 8753 Standard
ISO 3744 Test Condition
Life 40000 HOURS AT 25 ℃ -65% RH
No. of Blade 5 Blades
No. of Pole 2 Pole
Rotating Direction Counter-Clockwise view from label side
Tolerance ± 10% At Rated Voltage
Weight 446 g
Motor Type SHADED POLE, IMPEDANCE PROTECTED
IP rating IP55
 
Main Materials / Parts Specification
Materials / Parts Specification
Housing DIE CAST ALUMINUM PANINTED BLACK
Blade PBT + FIBER GLASS FILLED UL 94V-0
Bearing 2 Ball Bearing
Lead Wires WIRE LEADS UL #1430 22AWG
Connector None
 
Environmental Specification
Item Specification / Condition
Operating Temp. Range Temperature : -10°C ~ + 70°C
Humidity : 35% - 65% RH
Storage Temperature Temperature : -20°C ~+ 75°C
Humidity : 35% - 65% RH
Humidity

Per MIL-STD 202F Method 103B; Life: 96 hours;
Humidity : 95% RH; Temperature: 40 ± 2°C

Thermal Shock Per MIL-STD 202F Method 107D, Condition D
Insulation Shock UL: Class A
Packing Vibration Test Packing Condition: X, Y, Z 3directions, 1.1 G load vibration test for 30 min.
Packing Shock Proof Test 1 corner, 3 edges, 6 faces natural drop from 60 cm high packing
Shock Test Apply peak acceleration 50g and keep duration of the pulses for 11ms (Half Sine wave)
 
Electrical Specification
Item Specification/Condition
Insulation Resistance 10MΩ between frame and unshielded wire at
500VDC/min
Dielectric Strength 5mA Max. / Measured b/w lead wire (+) and frame at 500VAC/min
Locker Rotor Protection a. No damage will be made for a continuous 72-hour rotation lock at rated voltage.
b. Signal Alarm-Optional
Polarity Protection Circuit is protected when Vcc & GND are exchanged.